Eswab Instructions

(For Rapid RSV or Rapid Influenza virus, Adenovirus, or parainfluenza. Container/Tube: ESwab. Under these conditions, aerobes and anaerobes will survive 24 to 72 hours when properly collected in the anaerobic transport tube. 221010 - BD BBL™ SIM Medium, 'K'-Size Tube : 16,5x102 mm. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. On average, both systems maintained similar viabilities among analogous groups of organisms at both temperatures, although there were. ESwab is a liquid based multipurpose collection and transport system that maintains the viability of aerobic, anaerobic and fastidious bacteria for up to 48 hours. Submit only 1 of the following specimens: Specimen Type: Body fluid. If the tube spills its contents prior to inserting the swab, the liquid is non-toxic. Add 1 drop of the Negative or Positive control into the tube. We also ask that all facilities' nursing staff do not freeze any swabs. Additionally ESwab® can be used for Gram stains, automation, rapid antigen testing* and molecular assays*. For Regan-Lowe transport medium, collect specimen using mini-tip calcium alginate or dacron swab. Dry swabs, swabs in non-sterile transport devices, viral media, or refrigerated and/or frozen swabs are unacceptable. Viral cultures should be submitted on ice, or using a room temperature stable viral transport media such as COPAN UTM™. Collection Instructions: 1. ESwab™ collection and transport system helps collect clinical specimens containing aerobic, anaerobic and fastidious bacteria from the collection site, and transport them to the testing laboratory. 004 For in vitro diagnostic use. Group B Culture GBSCS Strep. Mid-Stream Urine Collection Instructions English. If the tube spills its contents prior to inserting the swab, the liquid is non-toxic. It may be possible to detect this odor momentarily when first opening the ESwab peel pouch. ESwab Copan Venturi Transystem Liquid Stuart single or double swab See Microbiology Collection Appendix for collection instructions. doc — Microsoft Word Document, 74 kB (75,776 bytes) Navigation. Pull the swab from its package. 85% Saline; BBL™ Leptospira Enrichment. Respiratory Specimens A. ESwab™, or saline. PrimeStore MTM offers FDA cleared safe, ambient temperature, sample collection and transport for RNA and DNA testing. Use of swabs for submitting specimens usually provides an inadequate sample to rule out a Mycobacterial or fungal infection. A gel bacterial swab is not acceptable. Rectal swab. No more flipping through pages and pages of user manuals. Swab the tonsil area thoroughly and behind the uvula. Storage for 24 hours at 4°C and RT resulted in 32 (91%) cultures. This swab type is acceptable for both culture and Gram stain. Eswab standard. Holding the swab cap with both swabs attached, sample each nares one at a time. Eye, Genital tract, Rectal or Throat using a eSwab transport system; Instructions. Thiamine (vitamin B1) is reported. Specimen is unacceptable if received without fluid or swab in the transport tube. refer to patient instructions for occult blood collection. Remove the screw cap. Storage of specimens in the ESwab™ transport at room temperature for greater than 48 hours may result in diminished recovery of certain anaerobic species. Label container with two patient identifiers (full name, DOB or MR), specimen source, and date and time of collection. Rejection Criteria: Collection Instructions: TESTING: TEST INFORMATION:. auris is an emerging multidrug-resistant fungal pathogen that can cause invasive infections. Gently insert the sterile Eswab until resistance is met, less than one inch into the nostril Rotate the swab a few times against the nasal wall and remove from nostril. If you detect resistance to the passage of the swab, back off and try reinserting it at a different angle, closer to the floor of the. ESwab™ combines a COPAN-invented flocked swab with 1mL of Liquid Amies in a plastic, screw cap tube. Click here to download ESwab white top collection device picture. For Regan-Lowe transport medium, collect specimen using mini-tip calcium alginate or dacron swab. Nasopharyngeal Collection Instructions Urine Collection Patient Instructions. In the lab, BD ESwab ™ specimens are processed using standard clinical lab operating procedures for bacterial culture. ESwab, Minitip Flocked Swab with Liquid Amies Medium, order by case of 500, by Copan Due to tremendous demand relating to COVID-19, we are not accepting "Guest" orders for this product at this time. Penile (urethral) swabs. Acceptable: Swab in transport media: M4, M4-RT, M5, M6, universal transport media, or ESwab. Media types: VTM, UTM, M6, ESwab, or sterile saline or Aptima Multitest Swab kit media ; Swabs must be placed in 1-3 mL of liquid media, broken or cut at the top of the tube, and tubes tightly capped. Especially for fastidious anaerobes. transport media, ESwab acceptable for tracheal secretions only, at ambient temperature. In the lab, BD ESwab ™ specimens are processed using standard clinical lab operating procedures for bacterial culture. POSTER PRESENTATION INSTRUCTIONS POSTER Viewing: Thursday, May 3 Posters: PT01 – PT17 Location: Grand Ballroom, Sheraton Vancouver Wall Centre Viewing Times for THURSDAY, MAY 3: • Lunch 12:30-14:30 o POSTER PRESENTERS (PT) MUST BE AT THEIR POSTERS TO ANSWERS QUESTIONS! • Meet & Greet Reception 17:15-19:00 Poster Set-Up Time for THURSDAY. Acceptable: Swab in transport media: M4, M4-RT (T605), M5, M6, universal transport media, or ESwab. Do not touch cotton end with fingers. Collection Container/Tube: Culturette swab (Dacron or rayon swab with aluminum or plastic shaft with either Stuart or Amies liquid medium. In addition to the immediate culturing and testing, all clinical specimens in the FecalSwab and ESwab devices were recultured and retested, as mentioned above, after being stored at 4°C and RT for 20 h. OP or NP washes/aspirates in sterile cups. Place the specimen in the big inner pocket of the plastic biohazard bag provided. Indicate source. 1:52 Simply put the swab into another tube before sending it to the laboratory and discard the spilled tube. 24-Hour Urine Collection Instructions English. (You should never douche. FecalSwab ® combines a COPAN-invented flocked swab with 2mL of Cary-Blair medium in a plastic, screw cap tube. Label with 2 patient identifiers. 5 Not all programs/sites may have the resources (e. Penile (urethral) swabs. To improve test sensitivity by detecting lower amounts of SARS-CoV-2 RNA, Truckee Applied Genomics proposes COVID-19 test developers use TAG-NGPM™ (Next Generation Pathogen Media) as a replacement for all current specimen collection and transportation media including: Universal Transport Media (UTM), Viral Transport Media (VTM – including. Group B Culture WITH sensitivity Strep Screen Vaginal/Rectal GP B, GBS Vaginal and/or rectal swab submitted in ESwab. Collection Instructions: Oral or vaginal swab collected in an ESwab mini-tip transport system (blue-cap) The significance of a yeast isolate varies with the organism identification, source, and clinical symptoms manifested. Specimen Volume: Entire specimen. Wash your hands before starting. Collect specimen by swabbing back and forth over mucosa surface to maximize recovery of cells. Any use of this material without the express written consent of Copan Diagnostics is prohibited. However, since it usually takes much longer to transport […]. 003 Aptima™ PATIENT INFORMATION REGARDING SELF-COLLECTED SPECIMENS • A self-collected swab is one way to test for sexually transmitted infections (STIs). Clean surface of lesions with alcohol. Clean instruments and surrounding surfaces according to instructions provided in the cleaning section of the instrument User Manual using 5-10% bleach solution followed by isopropanol. Multipurpose collection and transport system - ESwab™ is the only universal liquid-based, multipurpose, open platform collection and preservation system that maintains viability of aerobic, anaerobic and fastidious bacteria for up to 48 hours at refrigerator and room temperature. Find documentation, training and education, specifications and other information for Roche Diagnostics USA products for Core Laboratory, Molecular and Tissue Diagnostics, and Point of Care. The two others samples were analysed in mycology and parasitology. Check expiration date on. Once a swab sample is collected, it should be placed immediately into the ESwab transport tube where it comes into contact with the transport medium. It spreads easily through water droplets in the air from coughs or. Insert the swab approximately 2 cm (approximately 3/4 inches) into one nostril. Flocked swabs were stored in ESwab Liquid Amies (Copan) at room temperature (RT) and 4°C and cultured after 1, 24 and 48 hours. If the address matches an existing account you will receive an email with instructions to retrieve your username. Anus, (back passage) 1. Handling Instructions Transport swabs at room temperature, ideally within 4 hours of collection. or eSwab (plastic shaft with white cap) with Swab. Gently insert the swab into the nostril. It spreads easily through water droplets in the air from coughs or. Collect specimen from suspected sites per physician’s orders using an eSwab transport system. Unacceptable: Specimens other than swab or CSF. Collect eSwab of eye, genital tract, rectal or throat area using a eSwab transport system. Copan eSwab - White (Regular size) Room Temperature: Alternate 2: 1 Swab : Swab : Copan eSwab - Green (Mini-tip) Room Temperature: Instructions: Regular size applicator Copan eSwab - White Avoid skin surfaces, mouth, oral, anal, and vaginal areas which have normal anaerobic flora. Clean instruments and surrounding surfaces according to instructions provided in the cleaning section of the instrument User Manual using 5-10% bleach solution followed by isopropanol. Centers for Disease Control and Prevention. If you encounter any problems or need assistance, please call the. Once the swab is in place, rotate it in a circular motion 2 times and keep it in place for 15 (ESwab) ESwab with 1 mL of Amies fluid in the transport vial (1 mL of volume may. Instructions for Obtaining Patient-Collected Aptima Vaginal Swab Specimens 1 IN0146 Rev. It’s also called a “wet prep. Rota-Strip buffers exchange between different lots will not give. (Stool in container with preservative is not acceptable. In the privacy of the examination room or re stroom, you will need to undress from the. The result is evidence-based, improved pathogen recovery, expanded testing capabilities, and better patient care. Results From 35 patients with Ng positive NAAT, we obtained 34 (97%) Ng cultures from ESwab samples stored for 1 hour at RT. Printed: September 4, 2020 This printed copy may not contain the most current information, visit www.  Have patient blow their nose (if nasal)  Do not use lubricant (may use saline)  Rotate 2‐3 times Hold in place5seconds For more information,please call (800) 324‐7853. 003 Aptima™ 3 3 PATIENT INFORMATION REGARDING SELF-COLLECTED SPECIMENS • A self-collected swab is one way to test for sexually transmitted infections (STIs). ESwab system collects and releases more specimen, significantly improving patient test results and decreasing the need for repeat testing due to insufficient sample. Yersinia and Vibrio culture must be requested separately. ESwab and Universal Viral Transport 4 5 6 Swab Collection Reminders: Have patient blow their nose (if nasal) Do not use lubricant (may use saline) Rotate 2‐3 times Hold in place5seconds For more information,please call (800) 324‐7853. A pediatric nurse has posted an unpleasant-looking illustration of a test for COVID-19—the disease caused by the novel coronavirus—which has been shared more than 50,000 times. To improve test sensitivity by detecting lower amounts of SARS-CoV-2 RNA, Truckee Applied Genomics proposes COVID-19 test developers use TAG-NGPM™ (Next Generation Pathogen Media) as a replacement for all current specimen collection and transportation media including: Universal Transport Media (UTM), Viral Transport Media (VTM – including. Follow the instructions on the ESwab package for proper placement of swab into the collection tube. Uncap the BD MAX™ UVE Sample Buffer Tube. ESWAB IS EASY TO USE:. Always read the manufacturer’s package insert for specific instructions regarding specimen collection and transport for the type of test kit being used. NP swabs have a narrower flexible end and the swab head is. We compared the eSwab system to a swab with an anaerobic transport semisolid agar system for their capacities to maintain the viability of 20 species of fastidious anaerobes inoculated on the bench and held at ambient or refrigerator temperature for 24 or 48 h. A volume of 200 µl of ESwab allowed performing several different Aptima assays and the LOD of bacteria remained low whatever the storage conditions. Kit is designed to make specimen collection, transport, and storage easier by sustaining aerobic, anaerobic, and fastitious bacteria in one formulationUsing swabs in tubes will protect bacteriological, cytological, or serological samples during transportation to analyzing sites. Instructions: It is preferable for the patient to be off medications for 3 days before specimen collection. Insert the swab into a nare until resistance is met at the level of the. Follow the instructions in the TEST PROCEDURE to dispense the Extraction Reagents in to tube. If you have problems finding the documents, contact Technical Service at 800-255-6730, option 2 or e-mail microbiology. Collection with eSwab is acceptable if fluid or tissue cannot be collected. We’ve got everything you need right here in digital form. Avoid touching the swab applicator below the pink molded breakpoint as this could lead to contamination and incorrect test results. Double bag all specimens in biohazard bags for transport. Detect varicella-zoster virus (VZV). 24-Hour Urine Collection Instructions; Blood Culture Collection Guide; Body Fluid Collection Volumes; ESwab. Tilt your head back, look up at the ceiling, and gently insert the soft tip of the swab into one nostril until the safety stopper touches the edge of your nostril. Rejection Criteria: The following specimens will be rejected: specimens received in expired transport media. eSwab™ - Standard Tip Swab OR eSwab™ - Mini Tip Swab (preferable for pediatric and nasopharyngeal collection. The result is evidence-based, improved pathogen recovery, expanded testing capabilities, and better patient care. If Aspirating from the wound send to the laboratory the maximum amount of material (use sterile syringe, seal with sterile cap) and deliver to the laboratory as soon as possible. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft covering the score line. CLSI offers an entire library of method evaluation standards and method verification guidelines that provide concise explanations and step-by-step instructions for evaluation of test method performance characteristics such as precision and accuracy. Introduce tissue into tube avoiding tipping tube. Instructions Mini-tip swabs must be used for nasopharyngeal specimens and placed in ESwab or Regan-Lowe transport medium. Using the same swab, repeat for the other nostril. Available in 3 flocked swab formats – regular, minitip and flexible minitip. Acceptable: Swab in transport media: M4, M4-RT (T605), M5, M6, universal transport media, or ESwab. Minimum volume 0. Simply put the swab into another tube before sending it to the laboratory and discard the spilled tube. Sputum for those patients with productive coughs. 3) Culture, Stool and Culture, VRE: Cary Blair (preferred). (BSARD) test is also requested on a single swab: Swab must be in LIQUID (not gel or ESwab) transport medium such as Stuart's. It is important to dispose of this specimen properly and according to your local regulations. Collection instructions:Use a collar/stopping point swab for collecting specimens from both nares of a symptomatic patient. Once the swab is in place, rotate it in a circular motion 2 times and keep it in place for 15 second s. Collect specimen by swabbing back and forth over mucosa surface to maximize recovery of cells. Si le prélèvement est réalisé sur les 2 oreilles,. 1) Perform hand hygiene and don personal protective equipment, including safety glasses, as required by Standard Precautions. Transport: Critical Refrigerated. Kit is designed to make specimen collection, transport, and storage easier by sustaining aerobic, anaerobic, and fastitious bacteria in one formulationUsing swabs in tubes will protect bacteriological, cytological, or serological samples during transportation to analyzing sites. Collection Container/Tube: Culturette swab (Dacron or rayon swab with aluminum or plastic shaft with either Stuart or Amies liquid medium. the manufacturer's instructions. Sekisui Diagnostics has a broad product portfolio to meet your diagnostics needs. Note that these instructions are applicable for respiratory viruses in general, and not specific for only influenza virus. Label with 2 patient identifiers. The BD ESwab ™ collection and transport system helps collect clinical specimens containing aerobic, anaerobic and fastidious bacteria from the collection site, and transport them to the testing laboratory. • Copan-Eswab™ system. ■Perform positive patient identification. Taking a nasopharyngeal specimen for COVID-19 is as simple as a performing flu test. Open the peel pouch and remove the contents. ESwab Copan Venturi Transystem Liquid Stuart single or double swab See Microbiology Collection Appendix for collection instructions. Anus, (back passage) 1. If the tube spills its contents prior to inserting the swab, the liquid is non-toxic. Both specimens were stored at RT before and during testing. If you detect resistance to the passage of the swab, back off and try reinserting it at a different angle, closer to the floor of the. 1000 reactions. There are two different types of strep swabs. , Interface/Connect/Manual Requisitions); as this can delay results and contribute to compromised specimens. Aseptically inject all abscess material on top of agar. Instructions for Use. E-Swab Instructions Perform hand hygiene and put on gloves if necessary. The first slide was prepared using 100. Place the tightly sealed and labeled Copan eSwab collection tube into the biohazard bag. GC Chlamydia Urine Collection Instructions Spanish. Container/Tube: ESwab collection kit. As a visual reference, the swab should be. Culture and polymerase chain reaction (PCR) test for Bordetella pertussis Culture of urethral & eye specimens for Neisseria gonorrhoeae. NP swabs are better than throat swabs for the detection of infection by other respiratory viruses (i. 7016 • acllaboratories. Instructions At 35 to 37 weeks gestation, vaginal swab specimens are collected from the lower third of the vagina (vaginal introitus) and from the anal canal (a single swab from the vagina then the anal canal, or a swab collected from each site). Other options are available. yst t ompany. Specimen and Order Submission Quick Tips Submit one specimen per test (excluding allergens). Dry swabs or swabs sent in bacterial transport medium (eSwab). Uncap the BD MAX™ UVE Sample Buffer Tube. Use only synthetic fiber swabs with plastic or wire shafts. 221003 - ESwab Collection Kit Mini-Tip. Culture Transport Swab: Ambient (preferred) 24 hours/Refrigerated 24 hours Acceptable: Specimen Type: Prepared microscope slide. Instructions for Use and Certificates of Quality have moved to www. Food and Drug Administration authorized the first diagnostic test with a home collection option for COVID-19. 5 Not all programs/sites may have the resources (e. Bacterial cultures and viral cultures require different transport systems. The incidence varies depending on age and certain predisposing factors. Need a Reliable Diagnostic Partner? At Solaris Diagnostics, we make it easy! Our Results Portal allows you access patient reports quickly and securely online. Removed flocked swab (white shaft with red score) from the blue cap. Clean instruments and surrounding surfaces according to instructions provided in the cleaning section of the instrument User Manual using 5-10% bleach solution followed by isopropanol. Read More» DOI: 10. Leave the swab. As a visual reference, the swab should be. Oropharyngeal (OP) collection in viral transport medium, ESwab™, or saline. IMMEDIATELY place in properly labeled ESwab collection/transport tube, breaking off at scored red line. Remove surface exudate by wiping with sterile saline or 70% alcohol. 004 For in vitro diagnostic use. Specimen and Order Submission Quick Tips Submit one specimen per test (excluding allergens). This odor is a perfectly normal. Avoid touching the tongue, cheeks, and teeth with the swab. Welcome to the WakeMed Pathology Find A Test. The innovative system elutes over 90% of patient specimen into the liquid medium. Fluid sent in a capped syringe should be set up at the Off-site Labs per Lucidoc instructions. Use an ESwab to collect urethral discharge. Use of the ESwab for the Detection of MRSA: a Comparison between Two Different Commercial PCR Methods. Specimen Preparation: Transport rectal swab in eSwab transport media (ARUP Supply #45877) available online through eSupply using ARUP ConnectTM or contact ARUP Client Services at (800) 522-2787. Special Instructions: Submit one specimen per patient in an individually sealed bag. Vagina, (front passage) 2. Individually packaged Sterile Multipurpose collection and transport system - ESwab™ is the only universal liquid-based, multipurpose, open platform collection and preservation system that maintains viability of aerobic, anaerobic and fastidious bacteria for up to 48 hours at refrigerator and room temperature. Specimen tubes should be labeled with two unique patient identifiers. Screw on the cap on tightly. The laboratory is regulated under CLIA as qualified to perform high-complexity testing. Similarly, a second glass slide was prepared by using an amount of 30 μl from each ESwab ® tube. Solaris Testing Panels Click a panel type to learn more. Remove swab from packaging. Collect eSwab of eye, genital tract, rectal or throat area using a eSwab transport system. Register Now Solaris Diagnostics Test Panels At … Panels Read More ». We pioneered the very concept of animation art restoration and are renowned worldwide for the consistent high quality of the art we offer for sale through our Lab Listings. ESwab Liquid-Based Collection and Transport System by Copan Manufacturer: Copan Diagnostics Inc Each system includes a1 mL liquid amies medium, a polypropylene, screw-cap tube with internal conical shape and a nylon-flocked swab. However, common antihypertensives (diuretics, ACEinhibitors, calcium channel blockers, alpha and betablockers) cause minimal or no interference. Johns Hopkins Medical Microbiology Specimen Collection Guidelines – Updated 6/2019 1 Overview The proper collection of a specimen for culture is the most important step in the recovery of pathogenic. Insert biohazard bag into foam shipping bag. The ESwab was processed according to the instructions in the package insert. Centers for Disease Control and Prevention. Using a flocked or spun polyester swab, insert the swab at least 1 cm (0. Note: Specimen source is required. Ordering the Tests(s):On the bottom of an Associated Pathologists Cytology requisition, on the lines above the word, “Confidential”, write boldly in all caps, “DO VAGINITIS PANEL. When the HPV virus is present in the throat, it lodges itself in the deep crevices of the throat area. The VERIGENE Test Cartridge is a single-use, self-contained test unit comprised of the following: Reagent Pack—A microfluidic cassette that contains all of the hybridization reagents needed for a single test and captures the waste materials generated during test processing. eSwab™ collection video. Ship refrigerated. Other options are available. NP swabs and throat swabs have equivalent sensitivity for COVID-19. Collection Instructions. Quality products for laboratory and research environments. Screw on cap tightly. Wash your hands before starting. Place swab back into swab cylinder. 221004 - Eswab Collection Kit Flexible Mini-tip.  Have patient blow their nose (if nasal)  Do not use lubricant (may use saline)  Rotate 2‐3 times Hold in place5seconds For more information,please call (800) 324‐7853. Place a clean Swab into the Tube and follow the instructionsfor testin the patient Swab. Mid-Stream Urine Collection Instructions English. This may include: In the 2 days before the test, DO NOT use creams or other medicines in the vagina. The Eswab fluid maintains the viability of diverse bacteria. Rotate the swab against nasal mucosa. Careful compliance with the instructions in the Copan Liquid Amies Elution Swab (ESwab) Collection and Transport System package insert is necessary to avoid erroneous results. eswab amies reg flock swab Features Multipurpose collection and transport system - ESwab™ is the only universal liquid-based, multipurpose, open platform collection and preservation system that maintains viability of aerobic, anaerobic and fastidious bacteria for up to 48 hours at refrigerator and room temperature. Any exudate should be touched, and care should be taken to avoid tongue and uvula. Please contact your Hardy Sales Representative for further information or Customer Service to place an order. Submit only 1 of the following specimens: Specimen Type: Body fluid. ESwab system collects and releases more specimen, significantly improving patient test results and decreasing the need for repeat testing due to insufficient sample. 221004 - Eswab Collection Kit Flexible Mini-tip. To expedite specimens to the lab and avoid delays in processing, it is essential to provide complete information with each specimen: Patient Name & Age. com for the latest information. Insert swab 2cm into vagina, (front passage). Otherwise, the patient must freeze the specimen. Copan Diagnostics ESwab™ Patented Sample Collection and Delivery System, Non Capture Cap Liquid based collection and transport device for aerobic, anaerobic, and fastidious bacteria for up to 48 hours. Molecular testing is generally preferred; refer to Varicella-Zoster Virus by PCR (). Sterilin e-Swab MRSA Collection Kit l Simplifies collection and transport of patient samples for MRSA identification l Premium performance l Ideal for pooling of samples. Aspirate abscess material with a needle and syringe. Handling Instructions Specify exact source of specimen and "R/O Anaerobes" for optimal workup Abscess fluid: Transport in syringe (expel air, remove needle and cap syringe), ideally within 2 hours of collection, but not more than 24 hours after collection. Allow to dry for 1 minute before inoculating. Specimen is unacceptable if received without fluid or swab in the transport tube. Peel apart package and remove transport. It has not been cleared or approved by the FDA. Collection Instructions: Patient's Name and demographics must be on the swab label Stool must be transferred to fecal swab within 2 hours of passage For patient collection instruction sheet see Addendum D For patient collection instruction sheet Spanish see Addendum D For patient collection instruction sheet Burmese see Addendum D. Puritan Medical Products Resource How to Swab for MRSA leverages the Center of Disease Controls nasal swab screening guidelines. The COPAN Eswab ® is thicker than the viral respiratory swab because the targeted site of sampling for MRSA is the anterior nares. See Instructions : Swab : Copan eSwab - White (Regular size) Room Temperature: Alternate 1: See Instructions : Swab : Copan eSwab - Green (Mini-tip) Instructions: For Aerobic Cultures Only. Always consult product inserts, instructions for use and manuals for the appropriate use of. Specimens for anaerobic culture should be maintained at room temperature. Virus isolation will be performed on Eswab samples if requested, but viral transport media is a superior media for recovery of viruses. CoPan ESwab with larger swab (CoPan ESwab with smaller swab, See Collection Instructions) Collection Instructions: Collect using CoPan ESwab. Remove the screw cap. Label with patient information. INSTRUCTIONS FOR NASOPHARYNGEAL SAMPLE COLLECTION USING ESWAB™ COLLECTION SUPPLIES Swab (1) Tube of medium (1) Position head slightly back. SCH Main Campus Specimen Collection: Sample should be collected on a BD ESwab. FecalSwab ® combines a COPAN-invented flocked swab with 2mL of Cary-Blair medium in a plastic, screw cap tube. E-Swab Instructions Perform hand hygiene and put on gloves if necessary. Culture Transport Swab: Ambient (preferred) 24 hours/Refrigerated 24 hours Acceptable: Specimen Type: Prepared microscope slide. Instructions Mini-tip swabs must be used for nasopharyngeal specimens and placed in ESwab or Regan-Lowe transport medium. 221012 - BD BBL™ Sabouraud Dextrose Agar Slants (pH 5. Insert swab into 1 nostril straight back (not upwards). Acceptable: Serum gel. Risk factors include impaired salivary gland function, drugs. Otherwise, the patient must freeze the specimen. Place swab back into swab cylinder. Copan Diagnostics ESwab™ Patented Sample Collection and Delivery System, Non Capture Cap Liquid based collection and transport device for aerobic, anaerobic, and fastidious bacteria for up to 48 hours. Seal biohazard shipping bag and insert patient demographics sheet in flap on back of bag. Inject up to 5 ml of fluid into the transport media through the rubber port. Copan eSwab - White (Regular size) Room Temperature: Alternate 2: 1 Swab : Swab : Copan eSwab - Green (Mini-tip) Room Temperature: Instructions: Regular size applicator Copan eSwab - White Avoid skin surfaces, mouth, oral, anal, and vaginal areas which have normal anaerobic flora. ESWABTM INSTRUCTIONS ESWABTM IS EASY TO USE:. Break off the swab at edge of tube at the molded mark. BD ESwab is 1 mL of Modified Liquid Amies packaged with a nylon flocked swab. • Do not use a collection system that contains charcoal or semisolid transport media. Purchase information will also be available soon on our diagnostic supply request form. Acceptable: Culture transport swab (Stuart's media) or place swab in M4, M4-RT (T605), M5, M6, UTM, or ESwab. Unpreserved stool must be received in the Microbiology Laboratory within 2 hours of. Specimen is unacceptable if received without fluid or swab in the transport tube. Maintain sterility and forward promptly. Avoid touching the tongue, cheeks, and teeth with the swab. Group A Dual Swab Collection Instructions (Eswab) Lock Box Usage Instructions; Lead Testing Demographic Form; Order of Draw Instructions; 2020 and Prior Respiratory Data; QuantiFERON TB Gold Blood Collection Guide; QuantiFERON TB Gold Collection Tubes; Specimen Collection Guide Posters. The event description provided indicates that during collection of routine throat culture from adult pt by an experienced er staff member, using the eswab collection and preservation swab (copan brand) for strep throat culture, the swab broke in correspondence of its breaking point inside the pt's mouth, leaving the plastic piece inside her. Ship refrigerated. Depress tongue and rub swab vigorously over each tonsillar area and posterior pharynx. To request access to the Providers Results Portal, please complete our Provider Registration form. Always read the manufacturer’s package insert for specific instructions regarding specimen collection and transport for the type of test kit being used. This quick how-to video walks healthcare professionals through how to swab. Specimen tubes should be labeled with two unique patient identifiers. , 97 Murietta, CA). CoPan ESwab with larger swab (CoPan ESwab with smaller swab, See Collection Instructions) Collection Instructions: Collect using CoPan ESwab. Specimen Preparation: Transport rectal swab in eSwab transport media (ARUP Supply #45877) available online through eSupply using ARUP ConnectTM or contact ARUP Client Services at (800) 522-2787. Nasopharyngeal Swab Collection Instructions. Swab specimens should be immediately transferred to the ESwab transport tube, breaking the swab at the indicated score line. SRL Home Collect brings you the complete assurance of hygiene with the use of BUC Box. Trichomonas vaginalis antigen testing using an eSwab collection container was developed and its performance characteristics determined by Regional Medical Laboratory. Transport swabs and microbiology swabs: A mix of throat swabs, pertusis swabs, culture swabs, charcoal swabs, nasopharyngeal swabs with amies transport medium. When to use the ESwab™ • The “Specimen Collection Guide” on the back of the Medical Directives (M004: “ARO Admission Screen” and M022: “ARO Surveillance Orders”) will be revised with the new ESwab™ instructions • Available to order from printing services June 2, 2016. Simply put the swab into another tube before sending it to the laboratory and discard the spilled tube. Peel apart package and remove transport. Instructions for Using the Aptima™ Multitest Swab Specimen Collection Kit for Patient-Collected Specimens 1 AW-14334-001 Rev. COVID-19: Information for healthcare professionals During the COVID-19 health crisis, fast action and trusted information matter more than ever. Amies liquid elution swab (ESwab) ESwab with 1 mL of Amies fluid in the transport vial (1 mL of volume may result in a Quantity Not Suffi-cient [QNS] if repeat testing of a specimen is needed. • Sample collection should be performed by specifically trained personnel using the recommended swabs. Pathology Call Center at 919-350-8242. 220246 - BD ™ ESwab Minitip Collection Kit Green cap w/Liquid Amies and a minitip flocked swab For eye, ear, nasal passages, nasopharynx and urogential tract. Instructions for Use and Certificates of Quality have moved to www. Open the peel pouch and remove the contents. It spreads easily through water droplets in the air from coughs or. Container/Tube: UTM, Culturette or Eswab. Medical Staff Bulletin (Jan 18, 2012) - Eswab conversion MSH. GC Chlamydia Urine Collection Instructions English. Page 1 of 3 *Source document: CDC Infectious Diseases Laboratories, Mycotic Diseases Branch. General guidance on how to use liquid eSwabs:ESWAB INSTRUCTIONS. A gel bacterial swab is not acceptable. ESwab Collection Guide Over ACL Client Services • 1. In ESwab medium, the LODs of CT, NG and MG were equivalent (between 1 and 10 IFU, CFU or CCU/mL) whatever the volume of ESwab added in the APTIMAÒ specimen transfer tubes. Minimum volume 0. 221000 - ESwab Collection Kit Regular. Conversion will begin December 3, 2019. Special Instructions. SwabCap® – FAQ’s When and how should I use SwabCap? SwabCap should be used on the unused needleless connectors on the catheter and tubing sets as soon as the catheter is placed. If the swab does not slide easily, gently rotate the swab as you push. Ideally, specimens must be promptly transported to the microbiology laboratory, preferably within 2 hours. Specimen Type. Place the specimen in the big inner pocket of the plastic biohazard bag provided. Insert the same swab 1cm into anus, (back passage). Do not send a dry swab as this will lead to unsatisfactory results. If you have problems finding the documents, contact Technical Service at 800-255-6730, option 2 or e-mail microbiology. Maintain sterility and forward promptly. Specimens collected on calcium alginate swab or wood shafted swab. Urethra or Cervical: 1. Special Instructions: Submit one specimen per patient in an individually sealed bag. Open swab pouch BD BBL CultureSwabs are available with regular, soft wire and aluminum wire. • Sustains viability of aerobic, anaerobic and fastidious bacteria in ONE formulation • Easy-to-use – Collect – Snap – Elute. Label with patient information. The incidence varies depending on age and certain predisposing factors. NP swabs and throat swabs have equivalent sensitivity for COVID-19. 2 mL of viral transport media. Anterior nares specimen. Some saliva drug test results exhibit different colored lines indicating different types of drug usage. Requisition blank - microbiology. Cardiology. Collection Instructions: Mini-tip swabs must be used for nasopharyngeal specimens and placed in ESwab or Regan-Lowe transport medium. Storage of specimens in the ESwab™ transport at room temperature for greater than 48 hours may result in diminished recovery of certain anaerobic species. Nasopharyngeal Collection Instructions Urine Collection Patient Instructions. Tilt patient head and insert swab into 1 nostril until the swab collar touches the outside of the nose. Sodium Thioglycollate has a natural sulfur-like odor. Repeat in other nostril using same swab Place swab directly in container and label. Insert an ESwab into the corresponding tube and break shaft at scored line OR place Puritan swab in a clean, dry plastic tube or sleeve. Using a flocked or spun polyester swab, insert the swab at least 1 cm (0. Tilt patients head back approximately 70 degrees and raise the tip of the nose. Acceptable: Swab in transport media: M4, M4-RT, M5, M6, universal transport media, or ESwab. ESwab Replacement and Instructions. 1:52 Simply put the swab into another tube before sending it to the laboratory and discard the spilled tube. Maintain sterility and forward promptly. Specimen Preparation: Transport rectal swab in eSwab transport media (ARUP Supply #45877) available online through eSupply using ARUP ConnectTM or contact ARUP Client Services at (800) 522-2787. The ESwab Liquid Amies fluid maintains the viability of diverse bacteria. Can a patient stay in their room when the sample is collected?. The ESwab system collects and releases more specimen, significantly improving patient test results and decreasing the need for repeat testing due to insufficient sample. Need a Reliable Diagnostic Partner? At Solaris Diagnostics, we make it easy! Our Results Portal allows you access patient reports quickly and securely online. CPA: Send sample to Microbiology. Swabs should be retained at room temperature until and during courier transport. Note: swabshould not be bent priortosample collection. TISSUE Specimen **A preferred specimen type: 1. Some saliva drug test results exhibit different colored lines indicating different types of drug usage. Use an ESwab to collect urethral discharge. Specifically, the FDA re-issued the emergency use authorization. Minimum Volume: Eswab: 300uL of liquid media in Eswab container. Additional Info: NOTE: This culture is for E. Collection Container/Tube: Culturette swab (Dacron or rayon swab with aluminum or plastic shaft with either Stuart or Amies liquid medium. the manufacturer's instructions. Label with two unique patient identifiers, date. The incidence varies depending on age and certain predisposing factors. Home :: Washington State Department of Health. Collection Instructions: Vaginal: 1. Handling Instructions Transport swabs at room temperature, ideally within 4 hours of collection. This test quickly checks for signs of the influenza viruses A and B in a sample of secretions from your nose or throat. The first one, on Eswab® transport media, was directed to PCR analysis, including 16S RNA, viral and Acanthamoeba research and bacteriological culture. Leave the swab in place for a few seconds to absorb secretions. Influenza, commonly called the flu, is a disease that can move from person to person relatively easily, and can infect a large number of people. Swab specimens should be immediately transferred to the ESwab transport tube, breaking the swab at the indicated score line. Instructions for Obtaining Patient-Collected Aptima Vaginal Swab Specimens 1 IN0146 Rev. Collection Instructions: Collect specimen (aspirate or exudate) after disinfecting skin surface. Holding the swab cap with both swabs attached, sample each nares one at a time. Always consult product inserts, instructions for use and manuals for the appropriate use of. , 97 Murietta, CA). Follow the instructions in the TEST PROCEDURE to dispense the Extraction Reagents in to tube. Collection Instructions before providing them with a collection kit. creditservicesagentes. In one continuous motion, using Eswab: Swab 1 tonsillar area up then down. The FDA cleared collection and transport system is suitable for enteric pathogen recovery using traditional bacteriology culture. We compared the eSwab system to a swab with an anaerobic transport semisolid agar system for their capacities to maintain the viability of 20 species of fastidious anaerobes inoculated on the bench and held at ambient or refrigerator temperature for 24 or 48 h. Collect specimen by swabbing back and forth over mucosa surface to maximize recovery of cells. Sanford Laboratories will accept old swab collection devices through Jan 15, 2020 to allow departments to use up current supplies. This test quickly checks for signs of the influenza viruses A and B in a sample of secretions from your nose or throat. Utiliser l'écouvillon fourni avec le kit et suivre les instructions (écouvillon à prélever en premier pour augmenter la sensibilité du test) OREILLE o Réaliser 1 écouvillon (ESWAB pour prélèvement urétral) par oreille en fonction de la prescription. Careful compliance with the instructions in the Copan Liquid Amies Elution Swab (ESwab) Collection and Transport System package insert is necessary to avoid erroneous results. ESwab and Cepheid's Xpert MRSA Assay team up to enhance detection of MRSA from Nasal Swabs!. Specimen and Order Submission Quick Tips Submit one specimen per test (excluding allergens). Printed: September 4, 2020 This printed copy may not contain the most current information, visit www. following the manufacturer’s instructions; 60 mL was eluted from the 200 mL starting material, and 5 mL of the eluate was tested by means of reverse-transcription polymerase chain reaction (RT-PCR) with the use of the TaqMan tech-nique. Nasopharyngeal Swab (recommended by CDC for initial diagnosis of COVID-19): Insert a swab into the nostril parallel to the palate. Rotate the swab against nasal mucosa. IMMEDIATELY place in properly labeled ESwab collection/transport tube, breaking off at scored red line. This odor is a perfectly normal. Place the swab in the tube so that it reaches to the bottom. 98 PCR compatibility. ESwab system collects and releases more specimen, significantly improving patient test results and decreasing the need for repeat testing due to insufficient sample. The ESwab fluid maintains the viability of diverse bacteria. 3) Culture, Stool and Culture, VRE: Cary Blair (preferred). Holding the swab cap with both swabs attached, sample each nares one at a time. Simply put the swab into another tube before sending it to the laboratory and discard the spilled tube. Quality products for laboratory and research environments. , 97 Murietta, CA). Specimen Collection and Submission Instructions Candida auris Colonization Testing (Version 1) DOH 301-020 Page 1 of 2. Clean instruments and surrounding surfaces according to instructions provided in the cleaning section of the instrument User Manual using 5-10% bleach solution followed by isopropanol. Collect eSwab specimen using a sterile culture swab transport system. Regional Clinic collection : Samples collected on BD ESwabs are sent to Main Campus Microbiology for culture set up. Solaris Testing Panels Click a panel type to learn more. 50 ESwab™ Liquid Amies Collection & Transport Devices 480CFA * Average System Height and Depth based on touch screen angle. bacteria with COPAN ESwabTM. Nasopharyngeal Collection Instructions Urine Collection Patient Instructions. Back to Lab Catalog. CDC statistics state that syphilis affects less than one-half a person per 1,000 people. Label container with two patient identifiers (full name, DOB or MR), specimen source, and date and time of collection. Keep the swab near the septum and floor of the nose. CPA: Send sample to Microbiology. It may be possible to detect this odor momentarily when first opening the ESwab peel pouch. Based on this evaluation and in consultation with Medical Staff leadership, effective May 1, an IgG-only test is available for use to support our patient care effort. Follow the instructions on the ESwab package for proper placement of swab into the collection tube. DNA collection kit for humans that can capture samples producing high yields of double stranded, long fragmented DNA from buccal cells using traditional swabs. • No lubricant is used for the sample technique. Si le prélèvement est réalisé sur les 2 oreilles,. Exceeding transport time or refrigerating specimen may result in loss of viability for N. Follow any instructions from your provider on preparing for the test. Label with two unique patient identifiers, date, and source. By using UTM to transport your specimen, you maintain the capability to reflex negative samples to the diagnostic technology of your choice. No Nylon Most suited for oropharyngeal collections. After the collection and testing procedures, there may be a remainder of urine specimen left in the collection container. com for the latest information. Instructions for the collection of a genital swab for the detection of a group B streptococcus (GBS) 1. Specimens will be rejected if received > 24 hours after collection. Copan Diagnostics Nylon Flocked Dry Swabs in Peel Pouches are anatomically designed swabs to optimize analyte collection efficiency with improved patient comfort. Place swab back into swab cylinder. Place specimen in a leakproof screw-capped, sterile container. Testing for the COVID-19 coronavirus can be an unpleasant affair, with a doctor or nurse shoving a cotton swab deep into your nasal cavity to get a good sample. Refrigerate ESwab (DO NOT FREEZE) and freeze PCR microcentrifuge tubes within an hour of collection. tissue submitted in formalin. 221003 - ESwab Collection Kit Mini-Tip. Submit a raw clinical sample (not a culture isolate) for enterovirus PCR. Collection Container/Tube: Culturette swab (Dacron or rayon swab with aluminum or plastic shaft with either Stuart or Amies liquid medium. ESwab Copan Venturi Transystem Liquid Stuart single or double swab See Microbiology Collection Appendix for collection instructions. Wash your hands before starting.  After set up, refrigerate remaining sample. Leave at room temperature until lab pick-up. • Open the swab container and remove the swab, taking care not to touch the tip to any surface or lay it down. Keyword Research: People who searched copan eswab instructions pdf also searched. Handling Instructions Specify exact source of specimen and "R/O Anaerobes" for optimal workup Abscess fluid: Transport in syringe (expel air, remove needle and cap syringe), ideally within 2 hours of collection, but not more than 24 hours after collection. Eswab: Room temperature. eswab amies reg flock swab Features Multipurpose collection and transport system - ESwab™ is the only universal liquid-based, multipurpose, open platform collection and preservation system that maintains viability of aerobic, anaerobic and fastidious bacteria for up to 48 hours at refrigerator and room temperature. Sample Requirements. For frozen ESwab samples, one of five replicates at day 5 did not yield detectable RNA for the N3 target. es Eswab standard. Transport swabs and microbiology swabs: A mix of throat swabs, pertusis swabs, culture swabs, charcoal swabs, nasopharyngeal swabs with amies transport medium. ESwab: Transport Temperature: A=48hrs: Methodology: Culture: Days Performed: Mon-Sat: Special Instructions: Submit specimen in anaerobic transport system. The Sofia RSV Fluorescent Immunoassay (FIA) uses advanced immunofluorescence-based lateral-flow technology to detect respiratory syncytial virus (RSV) nucleoprotein antigen directly from nasopharyngeal swab and nasopharyngeal aspirate/wash specimens from symptomatic patients. Item Name: ESwab flexible mini-tip collection kit (blue) BD™ ESwab Collection Kit Flexible Minitip Flocked Swab (blue cap) for Nasopharyngeal bacterial culture, Influenza antigen, or RSV antigen More Info Add to Cart. Detect varicella-zoster virus (VZV). Always consult product inserts, instructions for use and manuals for the appropriate use of. Bronchial washing or bronchoalveolar lavage (BAL) specimens in sterile cups. Rotate the swab quickly and remove it. Removed flocked swab (white shaft with red score) from the blue cap. Rotate the swab against the anterior nasal mucosa for 3 seconds. A strep swab is a medical diagnostic test that uses a sterile cotton applicator to swab the throat for a sample of secretions. If you have problems finding the documents, contact Technical Service at 800-255-6730, option 2 or e-mail microbiology. Johns Hopkins Medical Microbiology Specimen Collection Guidelines – Updated 6/2019 1 Overview The proper collection of a specimen for culture is the most important step in the recovery of pathogenic. Using the same swab, repeat for the other nostril. Uquld Amles Elutlon Swab (ESwab) Collection and TransportSystem Instructions SpednCoflection Properspecimen collection from the patient Is extremely critical for successful Isolation and identtficatlon of infectious organisms. Printed: September 4, 2020 This printed copy may not contain the most current information, visit www. Both specimens were stored at RT before and during testing. The number of people infected with gonorrhea & chlamydia is at an all-time high. Douching can cause infection of the vagina or uterus. 5 mL Bx 100 or Each PM 5 Aerobic Culture Swab (ESwab) Bag 50 or Each PB 16 Gold SST 5 mL Bx 100 or Each PM 6 Anaerobic Culture Transport Tube Each PB 21 Red 4 mL (no additive) Bx 100 or Each PM 15. Nasopharyngeal (NP) swabs also accepted in viral transport medium (discard OP swab included with viral transport medium), ESwab™, or saline. 221010 - BD BBL™ SIM Medium, 'K'-Size Tube : 16,5x102 mm. Do not send a dry ESwab as this will lead to unsatisfactory results. It spreads easily through water droplets in the air from coughs or. STGEN Strep. PRINCIPLES OF THE PROCEDURE The BD Veritor System for Rapid Detection of Flu A+B is a qualitative, digital immunoassay for the detection of influenza. ^ Please contact your sales representitive for a full list of LIS and POC data management connectivity solutions. Use orange top urethral e-swab. Micro Collection Guide 2020; Molecular Collection Guide 2020. 2) pH / Reducing Substances: Stool must be delivered to lab within 1 hour of collection. or eSwab (plastic shaft with white cap) with Swab. The two others samples were analysed in mycology and parasitology. BD ESwab is 1 mL of Modified Liquid Amies packaged with a nylon flocked swab. If you encounter any problems or need assistance, please call the. Group A Dual Swab Collection Instructions (Eswab) Lock Box Usage Instructions; Lead Testing Demographic Form; Order of Draw Instructions; 2020 and Prior Respiratory Data; QuantiFERON TB Gold Blood Collection Guide; QuantiFERON TB Gold Collection Tubes; Specimen Collection Guide Posters. These results and readings can vary from kit to kit and hence you need to read instructions well before using. BD FecalSwab ™ collection and transport system. Instructions for penile meatal swab specimen collection: 1. Make stool and rectal sample collection easier with the COPAN FecalSwab. For shipment, place sample tubes and the submission form in separate zip-top bags in a labeled insulated shipping container, with cool packs for. Specimen Required. Use of swabs for submitting specimens usually provides an inadequate sample to rule out a Mycobacterial or fungal infection. Sample both nostrils with same swab. Do not spill the tube contents. Note that these instructions are applicable for respiratory viruses in general, and not specific for only influenza virus. Area: Bacteriology Refer Out: Provincial Health Lab Expected Time for Results: 1-2 weeks Notes:N/A: Throat swab: Culture and sensitivity (C&S) MS 349: Cobas Eswab. InfoSync (“InfoSync”) module.  Have patient blow their nose (if nasal)  Do not use lubricant (may use saline)  Rotate 2‐3 times Hold in place5seconds For more information,please call (800) 324‐7853. S/H instructions: Days Test Performed: Mon, Wed, Fri Submit: 0. Place the swab in the tube so that it reaches to the bottom. Maintain sterility and forward promptly. Indicate source. TISSUE Specimen **A preferred specimen type: 1. Special Instructions: Collect whole stool (minimum - swab) and place in a Stool container, or Rectal swab in Eswab transport tube if patient cannot produce stool. Collection Instructions. Dry swabs or swabs sent in bacterial transport medium (eSwab). Reported as Positive or Negative, Suspect with Ct values : PROCEDURES: Polymerase chain reaction : DELIVERY METHOD: Next day delivery or 2 day transit is recommended : SECTION GROUP: Molecular Diagnostics. Collection Instructions: Oral or vaginal swab collected in an ESwab mini-tip transport system (blue-cap) The significance of a yeast isolate varies with the organism identification, source, and clinical symptoms manifested. ESwab formula contains Sodium Thioglycollate, an important component for the performance of the product and the maintenance of organism viability. 98 PCR compatibility. 3) Stool Culture: Cary Blair (preferred). ESwab™, or saline. Systems, reagents, tests, enzymes and specialty biochemicals. Gently slide the swab 2 inches (5 cm) into the vagina. The Affirm testing result at 24 h postcollection was established as the nonreference standard for this matched-pair study design. Culture Transport Swab: Ambient (preferred) 24 hours/Refrigerated 24 hours Acceptable: Specimen Type: Prepared microscope slide. Ordering the Tests(s):On the bottom of an Associated Pathologists Cytology requisition, on the lines above the word, “Confidential”, write boldly in all caps, “DO VAGINITIS PANEL. ESwab is a liquid-based, multipurpose open platform, collection and preservation system that maintains viability of aerobic, anaerobic and fastidious bacteria for up to 48 hours at refrigerator an. Tilt patient’s head back to assist in opening the mouth as wide as possible and depress tongue with a tongue depressor so swab doesn’t touch oral mucosa or tongue. 003 Aptima™ PATIENT INFORMATION REGARDING SELF-COLLECTED SPECIMENS • A self-collected swab is one way to test for sexually transmitted infections (STIs). Remove the strew cap from the tube Break the ap licator. Transport Temperature: Room temperature. NOTE: If you have any questions about this procedure, please ask your doctor, nurse or care-provider. Sanford Laboratories will accept old swab collection devices through Jan 15, 2020 to allow departments to use up current supplies. Read More» DOI: 10. Do not touch cotton end with fingers. ) (Directions: Remove tube from wrapper. 85% Saline; BBL™ Leptospira Enrichment. Gently insert the swab into the nostril. If one is sampling a dry surface, it is recommended that a wet or moistened swab is used. Sources: Pericardial, peritoneal. Collection Instructions. ^ Please contact your sales representitive for a full list of LIS and POC data management connectivity solutions. Insert swab 2cm into vagina, (front passage). Follow appropriate infection control precautions during specimen collection. • Follow the April 10. Wash your hands before starting. Instructions for Obtaining Patient-Collected Aptima Vaginal Swab Specimens 1 IN0146 Rev. For the most up-to-date information, refer to the AHS Laboratory Services Laboratory Bulletins. 1:52 Simply put the swab into another tube before sending it to the laboratory and discard the spilled tube. The BD ESwab ™ collection and transport system is intended for the collection and transport of clinical specimens containing aerobic, anaerobic and fastidious bacteria. Categories Posts by Specialty. Uquld Amles Elutlon Swab (ESwab) Collection and TransportSystem Instructions SpednCoflection Properspecimen collection from the patient Is extremely critical for successful Isolation and identtficatlon of infectious organisms. pH of vaginal fluid – Use S/P pH Indicator Strips Range 3. Place swab back into swab cylinder. transport media, ESwab acceptable for tracheal secretions only, at ambient temperature. Si le prélèvement est réalisé sur les 2 oreilles,.